codes for 9,000-24,000 BTU Models (
ac split type 1 pk dan 2 pk )
S01 Room temperature
sensor failure Refer to detailed diagnostic
S02 Indoor coil
sensor failure Check sensor for continuity
S03 Humidity sensor
failure Replace indoor board
S04 Comp.
temperature sensor failure Check sensor for continuity
S05 Outdoor coil
sensor failure Check sensor for continuity
S06 Outdoor air
sensor failure Check sensor for continuity
S07 Outdoor current
sensor failure Replace outdoor board
E01
Indoor/outdoor communication failure Refer to detailed diagnostics
E02
HIC circuit failure (Compressor/Fan circuit) Refer to detailed diagnostics
E03
Outdoor unit OTP rom failure Refer to detailed diagnostics
E04
Peak current cut off Refer to detailed diagnostics
E05
PAM or Active circuit failure Refer to detailed diagnostics
E06
High compressor discharge temperature Refer to detailed diagnostics
E07
Indoor fan operating failure Refer to detailed diagnostics
E08 4
way valve switching failure (RV) Refer to detailed diagnostics
E09
No refrigerant protection Refer to detailed diagnostics
E10
DC compressor drive circuit failure Refer to detailed diagnostics
E11
Outdoor fan operating failure Refer to detailed diagnostics
E12
Error in outdoor unit Refer to detailed diagnostics
E13
Freeze prevention activated Refer to detailed diagnostics
|